{"product_id":"accu-chek-guide-25-strips-reta","title":"ACCU-CHEK GUIDE BLOOD GLUCOSE TEST STRIPS 25 PIECES RETAIL PACK","description":"\u003ch1\u003e ACCU-CHEK\u003cbr\u003e Guide\u003c\/h1\u003e\n\u003ch2\u003e 25 Retail Strips\u003c\/h2\u003e\n\u003cdiv align=\"justify\"\u003e\n\n \u003cb\u003eDescription\u003c\/b\u003e\u003cbr\u003e Accu-Chek Guide is the blood glucose monitoring system indicated for people with diabetes for home self-monitoring and for in vitro diagnostic use by healthcare professionals in clinical settings. \u003cbr\u003eThe Accu-Chek Guide system is a unique solution designed to meet the diverse needs of people with diabetes and healthcare professionals. The system's features, such as the patented, spill-proof oval bottle and new test strips with a large blood sample application area, represent a host of smart solutions that simplify blood glucose testing.\u003cbr\u003e The system offers excellent accuracy and precision. Accu-Chek Guide test strips have been subjected to a wide variety of tests, including external studies and extensive internal testing. Study results demonstrate that the test strips provide accurate and reliable readings under a variety of conditions.\u003cbr\u003e\u003cbr\u003e Accu-Chek Guide strips boast three main features: \u003cbr\u003e- Spill-resistant oval bottle: The innovative design of the strip container prevents spills and makes it easy to remove just one strip at a time. The oval shape makes it pocket-sized, and the protruding cap is easy to open.\u003cbr\u003e - Large blood sample application area: The new Accu-Chek Guide test strips allow you to apply a small blood sample anywhere on the wide tip, highlighted in yellow and intuitively indicated by red blood drops drawn near the area.\u003cbr\u003e - Excellent accuracy (10\/10): The Accu-Chek Guide system complies with ISO 15197:2013\/EN ISO 15197:2015 and offers accuracy exceeding the required requirements, ensuring reliable results.\u003cbr\u003e\u003cbr\u003e \u003cu\u003eTechnical specifications\u003c\/u\u003e :\u003cbr\u003e\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"1\" width=\"500\"\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Capillary aspiration of the sample\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Yes\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Reading time\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e \u0026lt;4 seconds\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Measuring range\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 10-600 mg\/dl\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Temperature range\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 4-45°C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Working humidity range\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 10-90%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Hematocrit range\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 10-65%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Use at altitude\u003c\/td\u003e\n\n \u003ctd align=\"center\"\u003eYes up to 3094 m above sea level\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Biological liquid used for the sample\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Capillary, venous, neonatal and arterial blood\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Minimum sample quantity\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 0.6 mcl\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Capillary absorption\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Yes\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Sampling method\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Automatic absorption by blood sample aspiration\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Principle of reading tests\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Electrochemical - FAD-dependent glucose dehydrogenase (GDH) enzyme\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Blood glucose meter to use\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Accu-Chek Guide\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/table\u003e\n\n\u003cbr\u003e \u003cu\u003eSystem accuracy\u003c\/u\u003e :\u003cbr\u003e 1. System accuracy results for glucose concentrations less than 100 mg\/dL (less than 5.55 mmol\/L):\u003cbr\u003e - within ±5 mg\/dl (within ±0.28 mmol\/l): 175\/186 (94.1%);\u003cbr\u003e - within ±10 mg\/dl (within ±0.56 mmol\/l): 186\/186 (100%);\u003cbr\u003e - within ±15 mg\/dl (within ±0.83 mmol\/l): 186\/186 (100%).\u003cbr\u003e\u003cbr\u003e 2. System accuracy results for glucose concentrations equal to or greater than 100 mg\/dL (equal to or greater than 5.55 mmol\/L):\u003cbr\u003e - within ±5 mg\/dl: 296\/414 (71.5%);\u003cbr\u003e - within ±10 mg\/dl: 404\/414 (97.6%);\u003cbr\u003e - within ±15 mg\/dl: 413\/414 (99.8%);\u003cbr\u003e  \u003cbr\u003e3. System accuracy results for glucose concentrations between 14 mg\/ml (0.78 mmol\/l) and 578 mg\/ml (32.1 mmol\/l):\u003cbr\u003e - within ±15 mg\/dl or within ±15% (within ±0.83 mmol\/l or within ±15%): 599\/600 (99.8%).\u003cbr\u003e\u003cbr\u003e \u003cb\u003eComponents\u003c\/b\u003e\u003cbr\u003e Composition of reagents:\u003cbr\u003e Mediator 6.6%;\u003cbr\u003e FAD-GDH enzyme 21.3%;\u003cbr\u003e Swab 22.6%;\u003cbr\u003e Stabilizer 0.3%;\u003cbr\u003e Non-reactive component 49.2%;\u003cbr\u003e\u003cbr\u003e \u003cb\u003eHow to use\u003c\/b\u003e\u003cbr\u003e Read the test strip package insert carefully.\u003cbr\u003e Place the sample on the suction area of ​​the strip, highlighted in yellow. Wait approximately 4 seconds for the measurement cycle to complete.\u003cbr\u003e The yellow test zone on the strip provides visual confirmation of correct sample application.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003e Lipemic (triglyceride) samples \u0026gt;1800 mg\/dL (\u0026gt;20.3 mmol\/L) may produce elevated glucose results.\u003cbr\u003e Do not use this system if you are receiving intravenous infusion of ascorbic acid.\u003cbr\u003e Do not use this system during xylose uptake testing.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eConservation\u003c\/b\u003e \u003cbr\u003eStore strips at a temperature between 4°C and 30°C.\u003cbr\u003e Test strips can be used until the expiration date indicated on the package.\u003cbr\u003e This applies to test strips from a new, unopened bottle, as well as test strips from a previously opened bottle.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eFormat\u003c\/b\u003e\u003cbr\u003e Pack of 25 strips.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eCod.\u003c\/b\u003e 08137358001\u003c\/div\u003e","brand":"ROCHE DIABETES CARE ITALY SPA","offers":[{"title":"Default Title","offer_id":50734366425422,"sku":"938807664","price":26.66,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0845\/6214\/9710\/files\/TE009-207260.jpg?v=1768760477","url":"https:\/\/farmaspeed.it\/en-eu\/products\/accu-chek-guide-25-strips-reta","provider":"Farmaspeed","version":"1.0","type":"link"}