{"product_id":"aerosol-mesh-sofarmapiu","title":"AEROSOL MESH SOFARMAPIU'","description":"\u003ch2\u003e SoFarma Plus\u003c\/h2\u003e\n\u003ch3\u003e MESH AEROSOL\u003c\/h3\u003e\n\u003cdiv align=\"justify\"\u003e \u003cb\u003eDescription\u003c\/b\u003e\u003cbr\u003e Compact, easy-to-use and lightweight aerosol for the treatment of respiratory disorders of the airways, such as bronchial asthma, acute bronchitis, tracheitis, swelling and sore throat.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eHow to use\u003c\/b\u003e\u003cbr\u003e Remove the medicine vial, clean and disinfect it before use.  \u003cbr\u003eInfusion of the medicine: open the lid of the ampoule and pour the medicine into the ampoule. Refer to the figure below.\u003cbr\u003e Close the lid of the ampoule.\u003cbr\u003e Insert the medicine vial into the main unit.\u003cbr\u003e Mount the mask (snorkel).\u003cbr\u003e Turn on the device: Press and hold the \"ON\/OFF\" button for more than 1 second, then the green indicator light will light up and the device will start nebulizing.\u003cbr\u003e Mode Switching: The device has two working modes: Level I and Level II. Level I is high nebulization speed mode, Level II is low nebulization speed mode. Patient can switch between Level I\/II by short pressing the ON\/OFF button according to treatment needs.\u003cbr\u003e Inhalation: hold the device in your hand, wear the mask or mouthpiece, inhale the nebulized medicine by breathing slowly and deeply.  \u003cbr\u003ePower off: Long press the ON\/OFF button, after 1 second the device stops nebulizing and turns off.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eCleaning and disinfection\u003c\/b\u003e\u003cbr\u003e Remove the medicine vial and accessories from the main unit.\u003cbr\u003e Open the lid of the ampoule and discard any remaining medication.\u003cbr\u003e Add 75% ethanol solution to the medicine vial, close the vial lid and leave for at least 10 minutes; you can shake gently for better disinfection.\u003cbr\u003e Immerse the accessories to be disinfected in a container together with an ethanol solution, and close the container. Immerse in the 75% ethanol solution for at least 10 minutes.\u003cbr\u003e Empty the disinfectant into the medicine vial, remove the accessories from the disinfectant, then rinse the vial and accessories several times with clean water.  \u003cbr\u003eFill the medicine vial with clean water, insert it into the main unit and let the device run for 10 minutes to clean the nebulization membrane.\u003cbr\u003e Use medical gauze after cleaning to absorb water and dry thoroughly.\u003cbr\u003e Clean the surface of the main unit with a cloth soaked in 75% medical alcohol, then dry with a clean, soft cloth or allow to air dry.\u003cbr\u003e Once all the above operations are completed, store the main unit, medicine vial and accessories in a dry and clean place. \u003cbr\u003eThe nebulization membrane is a component subject to consumption; the average life of the aerosol is about six months (considering three daily uses of 20 minutes each). Its useful life depends on the use, the drug and the cleaning to which it is subjected. If the device works but the nebulization does not occur or is insufficient, promptly replace the drug ampoule. (Contact the distributor to purchase drug ampoules).\u003cbr\u003e\u003cbr\u003e \u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003e There is an air hole on the lid of the medicine vial which should not be covered to ensure normal nebulization.\u003cbr\u003e During use, hold the device still and do not shake it forcefully.\u003cbr\u003e After pressing the ON\/OFF button, the device will have a short start-up period (within 1s), then it will perform nebulization.  \u003cbr\u003eWhen the medicine is about to run out, it is recommended to tilt the device slightly towards the user (the side button is closer to the user) so that the remaining solution can come into contact with the nebulizer blade for nebulization.\u003cbr\u003e Due to the different characteristics of drugs, the device may not automatically shut down when some drugs are used up, so the user should turn off the device manually to protect the nebulizer sheet from damage.\u003cbr\u003e If the vial does not contain any medicine or other liquids, the device will automatically turn off. After the automatic shutdown, it is normal to find some medicine inside the vial.\u003cbr\u003e The duration of each inhalation should not exceed 20 minutes; in case of discomfort during use, immediately turn off the device and consult a doctor promptly.\u003cbr\u003e During cleaning and disinfection, turn off the device and do not connect it to the mains.  \u003cbr\u003eDo not use purified or distilled water for nebulization.\u003cbr\u003e Do not boil the medicine vial and disinfection accessories, otherwise the parts may be deformed. Do not dry the parts in the microwave.\u003cbr\u003e The parts disinfected with the disinfectant must be completely cleaned, otherwise the residual disinfectant may cause a worsening of the symptoms.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eConservation\u003c\/b\u003e\u003cbr\u003e Store at room temperature.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eFormat\u003c\/b\u003e\u003cbr\u003e Pack of 1 piece.\u003c\/div\u003e","brand":"SO.FARMA.MORRA SPA","offers":[{"title":"Default Title","offer_id":51114539188558,"sku":"950409589","price":40.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0845\/6214\/9710\/files\/TE009-350233.jpg?v=1768767251","url":"https:\/\/farmaspeed.it\/en-eu\/products\/aerosol-mesh-sofarmapiu","provider":"Farmaspeed","version":"1.0","type":"link"}