{"product_id":"glucometro-con-monitor-pic-gluco-safe-1-pezzo","title":"PIC GLUCO SAFE GLUCOMETER WITH MONITOR 1 PIECE","description":"\u003ch1\u003ePic Safe Gluco Monitor\u003c\/h1\u003e\n\u003cdiv align=\"justify\"\u003e \u003cb\u003eDescription\u003c\/b\u003e\u003cbr\u003e Glucometer for measuring blood glucose.\u003cbr\u003e The glucose in the blood sample mixes with the reagent in the strip and generates a low electrical current. The level of electrical current generated depends on the glucose concentration in the blood.\u003cbr\u003e The Pic Safe Gluco Monitor measures the generated current and converts it into a blood glucose concentration value. This is displayed on the meter's LCD display.\u003cbr\u003e The 8-electrode strip ensures high accuracy and precision.\u003cbr\u003e\u003cbr\u003e \u003cu\u003eTechnical specifications\u003c\/u\u003e\u003cbr\u003e\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"3\"\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e Glucose measurement\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Specificity for glucose beta-D-glucose in blood\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Method and principle of operation\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Electrochemical potentiometric\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Enzyme composition of test strips\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Glucose dehydrogenase\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Test strips\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Pic Safe Gluco Monitor strips for Pic Safe Gluco Monitor blood glucose meters only\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Correlation\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Plasma equivalent\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Sample\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Fresh capillary, arterial, venous and neonatal whole blood\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Measuring range\u003c\/td\u003e\n\n \u003ctd align=\"center\"\u003e10-600 mg\/dL (0.6-33.3 mmol\/L)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Response time\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 5 seconds\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Sample volume\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Approximately 0.5 mcL\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Hematocrit range that does not alter the measurement\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 0-70%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Calibration\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Absent\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Sampling\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Capillary blood sample aspiration\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Use of alternative sites (AST)\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Allowed\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Memory capacity\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Last 1,000 results with date and time\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e External connection\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Data transfer capability to PC via Micro USB\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Output Specifications\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e USB connection cable available upon request\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Batterie\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 2 AAA type LR03 1.5V, lifespan approximately 12 months or 500 tests depending on measurement conditions\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Operating environment\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 5°C - 45°C (41°F - 113°F)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Humidity\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 10-90% (non-condensing)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Dimensions\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 55x90x26 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Weight\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 86 g (with batteries)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Display\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 40x41 mm, with backlight)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Strip insertion port\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Illuminated door\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Automatic shutdown\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e After 2 minutes of inactivity\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Operating altitude\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Up to 3,048 meters\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cbr\u003e \u003cb\u003eHow to use\u003c\/b\u003e \u003cbr\u003eTo obtain accurate results, allow the meter to acclimate to the environment in which it will be used. The operating temperature must be between 5°C and 45°C.\u003cbr\u003e If the ambient temperature is below or above the meter's operating range, a thermometer icon appears on the display. Move the meter to an environment between 5-45°C (41-113°F), wait 30 minutes, and then perform the test. Do not artificially heat or cool the meter.\u003cbr\u003e\u003cbr\u003e Remove a new strip from the container and close it tightly. Insert the strip into the dedicated port; the meter will turn on automatically. When the strip and blood drop symbol appear, the meter is ready to take a test.\u003cbr\u003e Bring your finger with the drop of blood close to the strip until the blue window is completely filled with blood. The blood is automatically drawn into the strip. \u003cbr\u003eIf the beep has been set, the meter will alert you that the test has begun. After blood is applied to the strip, a countdown from 5 to 1 begins and appears on the display. After the 5 seconds are up, the result appears on the screen in mg\/dL or mmol\/L.\u003cbr\u003e To obtain accurate results, do not allow more than 20 seconds to elapse between collecting the blood sample and measuring the blood glucose level. The blood sample must be at least 0.5 mcL. The meter stores the date and time of the measurement.\u003cbr\u003e\u003cbr\u003e If your test result is less than 70 mg\/dL or if LO appears, it could indicate hypoglycemia. This situation requires immediate medical attention. Although the result could be due to an unlikely error, it is best to intervene immediately and repeat the measurement later. \u003cbr\u003eIf your result is above 180 mg\/dL or the word HI appears, this could indicate hyperglycemia. If you have no symptoms, repeat the test first. If you continue to get the same results or have symptoms, consult your doctor about appropriate action.\u003cbr\u003e\u003cbr\u003e \u003cu\u003eCleaning the glucometer\u003c\/u\u003e\u003cbr\u003e Avoid dust.\u003cbr\u003e If you need to clean your blood glucose meter, carefully follow these instructions. Avoid getting blood, moisture, dirt, or dust into the test strip port to prevent the meter from malfunctioning.\u003cbr\u003e To clean the meter, use a damp, lint-free cloth. Wring out the cloth thoroughly before use. Do not use an abrasive cloth or antiseptic solution, as they may damage the screen.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eConservation\u003c\/b\u003e\u003cbr\u003e Keep your glucometer, strips, and control solution together with their respective manuals. \u003cbr\u003eStore strips at room temperature between 2°C and 30°C. Do not refrigerate or freeze. Freezing and thawing may cause inaccurate blood glucose results.\u003cbr\u003e Keep the strip insertion port free from dust.\u003cbr\u003e Avoid exposing the strips to moisture and direct sunlight, and store them in a cool, dry place. After removing the strip, tightly close the container. The strip container maintains the correct humidity. Therefore, do not transfer the strips to containers other than those provided.\u003cbr\u003e Keep Pic Safe Glucocontrol control solution at a temperature between 2°C and 30°C.\u003cbr\u003e Shelf life with intact packaging (test strips): 24 months.\u003cbr\u003e Shelf life after opening (test strips): 6 months.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eFormat\u003c\/b\u003e\u003cbr\u003e The package contains:\u003cbr\u003e - 1 glucometer,\u003cbr\u003e - 2 AAA LR03 1.5V batteries;\u003cbr\u003e - 1 glucometer user manual;\u003cbr\u003e - 1 quick guide;\u003cbr\u003e - 1 case.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eCod.\u003c\/b\u003e 0205600010000\u003c\/div\u003e","brand":"THERAS CONSUMER HEALTH SRL","offers":[{"title":"Default Title","offer_id":53257086337358,"sku":"974967198","price":25.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0845\/6214\/9710\/files\/TE009-268794.jpg?v=1768785339","url":"https:\/\/farmaspeed.it\/en-eu\/products\/glucometro-con-monitor-pic-gluco-safe-1-pezzo","provider":"Farmaspeed","version":"1.0","type":"link"}