{"product_id":"misuratore-pressione-automatico-literapid-wrist","title":"LITERAPID WRIST AUTOMATIC BLOOD PRESSURE MONITOR","description":"\u003cb\u003eDescriptive sheet\u003c\/b\u003e\u003cbr\u003e\u003ch1\u003e liteRAPID WRIST\u003c\/h1\u003e\n\u003ch2\u003e Automatic blood pressure monitor\u003c\/h2\u003e\n\u003cdiv align=\"justify\"\u003e \u003cb\u003eDescription\u003c\/b\u003e\u003cbr\u003e Automatic digital wrist blood pressure monitor.\u003cbr\u003e To measure blood pressure.\u003cbr\u003e For home and hospital use.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eHow to use\u003c\/b\u003e\u003cbr\u003e Remove watches, jewelry, etc. before putting on the wrist monitor.\u003cbr\u003e To obtain correct measurements, the sleeves must be rolled up and the cuff worn on bare skin.\u003cbr\u003e Apply the bracelet preferably to the left wrist, with the palm facing upwards. \u003cbr\u003eMake sure the edge of the cuff is approximately 1 - 1.5 cm away from the wrist joints.\u003cbr\u003e To ensure accurate measurements, fasten the Velcro strap securely around your wrist, so that there is no gap between the cuff and your wrist.\u003cbr\u003e If the cuff is not tight enough, the measurement values ​​may be inaccurate.\u003cbr\u003e Sit in a comfortable position with the wrist used for measurement resting on a flat surface.\u003cbr\u003e Rest your elbow on a table, so that the cuff is at the same level as your heart.\u003cbr\u003e Turn your palm up.\u003cbr\u003e Sit upright in a chair and take 5-6 deep breaths.\u003cbr\u003e With the meter turned off, press the START\/STOP button to turn the device on and start the measurement.\u003cbr\u003e Press the START\/STOP button to turn off the appliance, otherwise it will turn off within 1 minute.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003e Avoid contact with water and, if necessary, clean with a dry cloth.\u003cbr\u003e Avoid strong vibrations and shocks. \u003cbr\u003eAvoid dusty and temperature-unstable environments.\u003cbr\u003e Do not use abrasive cleaners or solvents.\u003cbr\u003e Avoid washing the bracelet with water.\u003cbr\u003e This device is not suitable for use on infants, children, or pregnant women. The device has not been validated for use on the patient groups listed above and may be dangerous. Its suitability for use on adolescents must be evaluated by a physician.\u003cbr\u003e The device is contraindicated for use in women who suspect they are pregnant, are pregnant, or have preeclampsia. In addition to causing inaccurate readings, the device's effects on the fetus are unknown.\u003cbr\u003e The device is not suitable for use on people with a wrist circumference outside the range of 13.5 to 19.5 cm.\u003cbr\u003e People with reduced cognitive abilities must use the device under supervision.  \u003cbr\u003eKeep out of reach of children, people with reduced cognitive abilities, or pets: the device contains small parts that may cause choking or internal injuries if swallowed.\u003cbr\u003e Blood pressure measurement is not indicated in cases of severe arteriosclerosis (hardening and loss of elasticity of the artery walls).\u003cbr\u003e If the cuff pressure reaches 300 mmHg, the cuff deflates automatically. If the wrist cuff does not deflate when the pressure reaches 300 mmHg, or if you experience discomfort during the measurement, remove the cuff from your wrist and press the START\/STOP button to stop inflation.\u003cbr\u003e Persons with implanted medical devices should consult their doctor before using the device.\u003cbr\u003e This device cannot be used simultaneously with high frequency surgical equipment.  \u003cbr\u003eThe device is not intended for use during patient transport outside of a healthcare facility.\u003cbr\u003e It is not intended for use on any extremity other than the wrist or for any function other than blood pressure measurement.\u003cbr\u003e To avoid measurement errors, avoid conditions of strong disturbing signals emitted by electromagnetic fields or fast electrical transient\/burst signals.\u003cbr\u003e Before use, the user must check that the appliance is in safe operation and in good condition.\u003cbr\u003e Taking blood pressure measurements too frequently can be harmful to the patient because it can compromise blood circulation. Verify (by observing the affected limb) that the operation of liteRAPID WRIST does not cause prolonged alterations to the patient's blood circulation.  \u003cbr\u003eThe unit is not suitable for continuous monitoring during medical emergencies or surgeries. Otherwise, the patient's wrist and fingers may become numb, swollen, and purple due to reduced blood flow.\u003cbr\u003e If, on rare occasions, the cuff remains fully inflated during measurement, open it immediately. Exerting high pressure on the wrist for prolonged periods (cuff pressure \u0026lt; 300 mmHg or constant pressure \u0026gt; 15 mmHg for more than 3 minutes) may cause ecchymosis (bruising).\u003cbr\u003e The device contains sensitive components and should be handled with caution.\u003cbr\u003e Use the appliance in the environments specified in the user manual. Failure to do so may compromise and reduce the appliance's performance and lifespan.\u003cbr\u003e Do not use if allergic to polyester, nylon or plastic.\u003cbr\u003e Applying the bracelet to a wound may cause further injury.  \u003cbr\u003eApplying the cuff and inflating it on limbs with intravascular access or therapy or arteriovenous shunts may cause injury to the patient as it causes temporary impairment of blood circulation.\u003cbr\u003e The device is not indicated for use by people who have undergone a mastectomy.\u003cbr\u003e Applying and inflating the cuff to the wrist of an arm on which a mastectomy has been performed may pose a risk of injury, and the measurement may not be accurate.\u003cbr\u003e Do not inflate the cuff on the same limb as another EM monitoring device, as this may cause temporary disruptions in the function of the other device.\u003cbr\u003e Non-AP\/APG type device, not suitable for use in the presence of flammable anaesthetic mixtures with air or with oxygen or nitrous oxide.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eMaintenance\u003c\/b\u003e\u003cbr\u003e Use a soft cloth to thoroughly clean the appliance before and after use. \u003cbr\u003eUse a damp cloth to remove dirt.\u003cbr\u003e It is recommended to check the performance every 2 years or after repair.\u003cbr\u003e The appliance should be rechecked if it is damaged by shocks and impacts (such as dropping) or exposure to liquids and\/or extreme temperatures (hot\/cold) or extreme changes in humidity.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eConservation\u003c\/b\u003e\u003cbr\u003e Store your device in a dry place and protect it from humidity, heat, dust and direct sunlight.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eFormat\u003c\/b\u003e\u003cbr\u003e The package contains the blood pressure monitor, the batteries needed to operate the instrument, the instructions for use, and the bag.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eCode\u003c\/b\u003e 0202253400000\u003c\/div\u003e","brand":"THERAS CONSUMER HEALTH SRL","offers":[{"title":"Default Title","offer_id":54185766420814,"sku":"989887765","price":84.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0845\/6214\/9710\/files\/TE009-348336.jpg?v=1768788006","url":"https:\/\/farmaspeed.it\/en-eu\/products\/misuratore-pressione-automatico-literapid-wrist","provider":"Farmaspeed","version":"1.0","type":"link"}