{"product_id":"misuratore-pressione-braccio-mc-evolution","title":"MC EVOLUTION ARM PRESSURE GAUGE","description":"\u003ch2\u003e MC EVOLUTION\u003c\/h2\u003e  \u003ch1\u003eUpper Arm Blood Pressure Monitor\u003c\/h1\u003e\n\u003cdiv align=\"justify\"\u003e \u003cb\u003eDescription\u003c\/b\u003e\u003cbr\u003e The monitor uses the oscillometric method to measure blood pressure.\u003cbr\u003e The automatic electronic blood pressure monitor is intended for use by medical professionals or at home to monitor and display diastolic, systolic blood pressure and heart rate on adults.\u003cbr\u003e\u003cbr\u003e \u003cu\u003eTechnical specifications\u003c\/u\u003e\u003cbr\u003e\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"3\"\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e Measurement method\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Oscillometric measurement\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Indication\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Digital LED display\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Measuring range\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Pressure: 30-280 mmHg\u003cbr\u003e Heart rate: 40-199 beats\/minute\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Precision\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Static pressure: ±3 mmHg\u003cbr\u003e Pulse: ±5%\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Memory\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 90 measurements\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Diet\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 4 x 1.5V batteries (LR03 or AAA)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Operating conditions\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Temperature: 5°C to 40°C\u003cbr\u003e Relative humidity: 15-93%\u003cbr\u003e Atmospheric pressure: 70-106 kPa\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Storage conditions\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Temperature: -20°C to +55°C\u003cbr\u003e Relative humidity: 0-93%\u003cbr\u003e Atmospheric pressure: 50-106 kPa\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Dimensions\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e approx. 93mm (W) x 161mm (H) x 47mm (D)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Classification\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Type BF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Upper arm circumference\u003c\/td\u003e\n\n \u003ctd align=\"center\"\u003e22-32 cm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Operating mode\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Continuous operation\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e AC adapter\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e Input: 100-240V, 50\/60Hz, 0.2A\u003cbr\u003e Output: 6V 500mA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cbr\u003e \u003cb\u003eHow to use\u003c\/b\u003e\u003cbr\u003e \u003cu\u003eInsert or replace batteries\u003c\/u\u003e\u003cbr\u003e Remove the battery cover. Insert new batteries into the battery compartment, making sure the polarity is correct. Close the battery cover. Use only LR03 or AAA batteries.\u003cbr\u003e\u003cbr\u003e When the low battery indicator flashes on the display, replace the batteries.\u003cbr\u003e Do not mix old and new batteries. This may shorten battery life or cause the device to malfunction.\u003cbr\u003e Use only the specified batteries. The batteries supplied with the device are for testing the monitor's performance and may have a shorter lifespan.\u003cbr\u003e Replace worn batteries with their polarities in the correct direction.\u003cbr\u003e If you will not use the unit for a long period of time (about three months or more), remove the batteries.\u003cbr\u003e  \u003cbr\u003e\u003cu\u003eAttaching the cuff to the arm\u003c\/u\u003e\u003cbr\u003e Wrap the cuff around your upper arm, about 2-3 cm above the elbow. Place the cuff directly on your skin, as clothing can cause a weak pulse and result in incorrect measurements.\u003cbr\u003e Constriction of the upper arm, caused by rolling up a shirt or t-shirt sleeve, can prevent accurate readings.\u003cbr\u003e Secure the cuff with the Velcro strip so it's comfortable and not too tight. Rest your arm on the table (palm up) so that the cuff is at the same height as your heart. Make sure the tube is not kinked.\u003cbr\u003e\u003cbr\u003e \u003cu\u003eBlood pressure measurement\u003c\/u\u003e\u003cbr\u003e To measure your blood pressure, sit comfortably without crossing your legs, with your feet flat on the floor. Remain still and quiet during the measurement. \u003cbr\u003ePress the ON\/OFF button; all icons will appear on the display for two seconds, then switch to measurement and display \"0\" or the last measurement record. Start measurement; the cuff will inflate automatically. The heart symbol will flash on the LED. Once the measurement is complete, the results will appear on the display.\u003cbr\u003e Measure your blood pressure at approximately the same time every day.\u003cbr\u003e Don't measure immediately after exercise or bathing. Rest for twenty to thirty minutes before taking the measurement.\u003cbr\u003e\u003cbr\u003e \u003cu\u003eCleaning and maintenance\u003c\/u\u003e\u003cbr\u003e Clean the monitor with a soft, dry cloth. Do not use any cleaning solutions.\u003cbr\u003e Do not immerse the device or any component in water.\u003cbr\u003e Clean the bracelet after each use. Wipe the inside (skin contact) of the bracelet thoroughly with a soft cloth lightly moistened with 75% ethyl alcohol three times. Replace the cloth after each use. Then air dry the bracelet.\u003cbr\u003e  \u003cbr\u003e\u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003e If you are taking any medications, consult your doctor to determine the best time to measure your blood pressure. Never change a prescribed medication without first consulting your doctor.\u003cbr\u003e For people with irregular or unstable peripheral circulation problems due to diabetes, liver disease, hardening of the arteries, etc., there may be fluctuations in blood pressure values ​​measured at the upper arm compared to the wrist.\u003cbr\u003e Measurements may be affected if this device is used near televisions, microwave ovens, X-ray equipment, cell phones, or other devices with strong electrical fields. To avoid such interference, use the monitor at a sufficient distance from such devices or turn them off.\u003cbr\u003e Wash hands before use. \u003cbr\u003eDo not measure on the arm that has been using ME equipment monitoring at the same time, otherwise it may cause loss of function.\u003cbr\u003e Batteries with liquid on their surface or that have been modified cannot be inserted into products.\u003cbr\u003e Short circuiting of the battery must be avoided.\u003cbr\u003e Battery life varies with ambient temperature and may be reduced at low temperatures.\u003cbr\u003e Do not immerse the device or any of its components in water.\u003cbr\u003e Do not expose the monitor to extremely hot or cold temperatures, humidity, or direct sunlight.\u003cbr\u003e Do not subject the monitor to strong shocks.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eFormat\u003c\/b\u003e\u003cbr\u003e 1 piece\u003cbr\u003e\u003cbr\u003e \u003cb\u003eCod.\u003c\/b\u003e MC1001\u003c\/div\u003e","brand":"MC EVOLUTION SRL","offers":[{"title":"Default Title","offer_id":50928020717902,"sku":"987755117","price":40.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0845\/6214\/9710\/files\/TE009-303377.jpg?v=1768764929","url":"https:\/\/farmaspeed.it\/en-eu\/products\/misuratore-pressione-braccio-mc-evolution","provider":"Farmaspeed","version":"1.0","type":"link"}