{"product_id":"test-autodiagnostico-one-step-strep-a-rilevazione-qualitativa-antigene-streptococco-a-in-tamponi-faringei-gammadis","title":"ONE STEP SELF-DIAGNOSTIC TEST STREP A QUALITATIVE DETECTION OF STREPTOCOCCUS A ANTIGEN IN GAMMADIS THROAT SWABS","description":"\u003ch1\u003e Wondfo\u003c\/h1\u003e\n\u003cdiv align=\"justify\"\u003e \u003cb\u003eDescription\u003c\/b\u003e\u003cbr\u003e Wondfo Streptococcus A Test is a lateral flow immunoassay for the qualitative detection of Group A Streptococcal antigen from throat swab specimens to aid in the early diagnosis of Group A Streptococcal infection.\u003cbr\u003e For in vitro self-testing. For self-testing.\u003cbr\u003e Group A Streptococcus is one of the most important human pathogens causing acute pharyngitis, tonsillitis, impetigo, and scarlet fever. \u003cbr\u003eIt is very important to differentiate streptococcal infection from other causative agents (e.g., viral, mycoplasmal, or chlamydial) so that appropriate therapy can be initiated. Early diagnosis and treatment of group A streptococcal pharyngitis infections will reduce the severity of symptoms and further complications such as rheumatic fever and glomerulonephritis. Therefore, it is helpful to have a home test on hand to be able to diagnose the infection at the first symptoms.\u003cbr\u003e When you add the sample to the sample well, capillary action causes the sample to migrate across the membrane.\u003cbr\u003e When group A streptococcal antigen levels in specimens are at or above the cutoff, a visible colored line appears in the test region, indicating a positive result. The absence of this colored line in the Test (T) region suggests a negative result. \u003cbr\u003eIf the test has been performed correctly, a colored line will appear on the control region (C) as a procedural control.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eHow to use\u003c\/b\u003e\u003cbr\u003e \u003cu\u003eSAMPLE COLLECTION AND PREPARATION\u003c\/u\u003e\u003cbr\u003e 1. Collect the sample with the sterile throat swab provided in the kit.\u003cbr\u003e 2. Hold your tongue down with a tongue depressor. Swab the back of your throat, tonsils, and other inflamed areas. Avoid touching your tongue, cheeks, and teeth with the swab.\u003cbr\u003e 3. The test should ideally be performed immediately after sample collection.\u003cbr\u003e\u003cbr\u003e \u003cu\u003eHOW TO PERFORM THE TEST\u003c\/u\u003e\u003cbr\u003e Bring the device and extraction reagents to room temperature (10°C-30°C) before performing the test.\u003cbr\u003e 1. Add 4 drops of extraction reagent A and 4 drops of reagent B to the respective extraction tubes and mix thoroughly. The mixed liquid should turn yellow. \u003cbr\u003e2. Place the sample extraction swab into the tube. Shake the swab ten times. Leave the swab in the tube for one minute. Then remove the swab, pressing the swab head against the inside of the tube as you remove it to remove as much liquid as possible from the swab. Discard the swab.\u003cbr\u003e 3. Cap the tube and mix the contents by shaking gently. The sample must be tested immediately.\u003cbr\u003e 4. Remove the test from the sealed foil pouch by tearing at the notch and place the test on a clean, dry, flat surface. Add 3 drops of mixed liquid sample from the tube to the sample well (represented by an arrow) of the test cassette by inverting and squeezing the tube.\u003cbr\u003e 5. Wait 10 minutes and read the results. Do not read the results after 15 minutes.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eReading the results\u003c\/b\u003e\u003cbr\u003e Positive \u003cbr\u003eIf two colored lines are visible in both the test (T) and control (C) regions, the result is positive. This indicates that you may be in a stage A Strep infection and should consult your doctor.\u003cbr\u003e Negative\u003cbr\u003e If only one colored line appears in the control region (C) and no colored line appears in the test region (T), the result is negative. This indicates that the concentration of group A streptococcal antigen is at or below the test's detection limit.\u003cbr\u003e Invalid\u003cbr\u003e No visible line or a single visible line in the test region but not in the control region. This indicates a procedural error and\/or deterioration of the test reagent. Repeat the test with a new kit. If the test is still invalid, please contact the distributor or the place where you purchased the product, providing the lot number.\u003cbr\u003e\u003cbr\u003e \u003cb\u003ePrecautions\u003c\/b\u003e \u003cbr\u003e1. This kit is for in vitro self-diagnostic use only. Do not ingest.\u003cbr\u003e 2. Do not interchange caps between reagents.\u003cbr\u003e 3. Do not use the test beyond the expiration date.\u003cbr\u003e 4. Keep out of reach of children.\u003cbr\u003e 5. Do not use the test if the pouch is punctured or not properly sealed.\u003cbr\u003e 6. Discard after use. The test is for single use only.\u003cbr\u003e 7. Avoid contact of reagents A and B with eyes, sensitive mucous membranes, cuts, abrasions, etc. If these reagents come into contact with skin or eyes, rinse thoroughly with water.\u003cbr\u003e 8. Do not eat, drink, or smoke in the area where the samples are kept and where the test will be performed.\u003cbr\u003e 9. Protective gloves should be worn when handling the sample. Wash your hands thoroughly after the procedure.\u003cbr\u003e 10. The device used, the swab and the extraction tube must be treated as contagious waste and therefore thrown into the containers for biohazard objects.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eLimitations\u003c\/b\u003e \u003cbr\u003e1. The results of this test should not be used to determine pharyngitis infections, since pharyngitis can be caused by organisms other than group A streptococcus. This test does not provide any information about pharyngitis other than that caused by group A streptococcal infection.\u003cbr\u003e 2. A negative result may occur due to insufficient amount of specimen collected, or insufficient addition of reagent A and BS and symptoms persist or intensify, always consult your doctor.\u003cbr\u003e 3. Excess blood or mucus in the collected sample may interfere with the performance of the test and could lead to a false-positive result. Do not touch your tongue, cheeks, teeth, or any bleeding areas of the mouth with the swab during sample collection.\u003cbr\u003e 4. As with any diagnostic procedure, a diagnosis should be confirmed only by a physician after evaluating all clinical and laboratory findings. \u003cbr\u003e5. Since the test kit contains a toxic composition and the highest rate of morbidity from upper respiratory tract infections has been found in children, the test should be performed by parents or another adult family member on all minors under 16 years of age.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eConservation\u003c\/b\u003e\u003cbr\u003e 1. Store at 4°C-30°C in the sealed package until the expiry date.\u003cbr\u003e 2. Keep away from sunlight, moisture and heat.\u003cbr\u003e 3. Do not freeze.\u003cbr\u003e 4. Preferably open the pouch just before performing the test.\u003cbr\u003e Please use the test kit within 1 hour of opening the pouch.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eFormat\u003c\/b\u003e\u003cbr\u003e 1 individually sealed sachet (containing test device, desiccant sachet);\u003cbr\u003e 1 extraction tube;\u003cbr\u003e 1 sterile throat swab.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eCod.\u003c\/b\u003e 101129\u003c\/div\u003e","brand":"GAMMADIS FARMACEUTICI SRL","offers":[{"title":"Default Title","offer_id":53052146975054,"sku":"987479437","price":9.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0845\/6214\/9710\/files\/TE009-329507.jpg?v=1768783680","url":"https:\/\/farmaspeed.it\/en-eu\/products\/test-autodiagnostico-one-step-strep-a-rilevazione-qualitativa-antigene-streptococco-a-in-tamponi-faringei-gammadis","provider":"Farmaspeed","version":"1.0","type":"link"}