MC EVOLUTION
Upper Arm Blood Pressure Monitor
Description
The monitor uses the oscillometric method to measure blood pressure.
The automatic electronic blood pressure monitor is intended for use by medical professionals or at home to monitor and display diastolic, systolic blood pressure and heart rate on adults.
Technical specifications
How to use
Insert or replace batteries
Remove the battery cover. Insert new batteries into the battery compartment, making sure the polarity is correct. Close the battery cover. Use only LR03 or AAA batteries.
When the low battery indicator flashes on the display, replace the batteries.
Do not mix old and new batteries. This may shorten battery life or cause the device to malfunction.
Use only the specified batteries. The batteries supplied with the device are for testing the monitor's performance and may have a shorter lifespan.
Replace worn batteries with their polarities in the correct direction.
If you will not use the unit for a long period of time (about three months or more), remove the batteries.
Attaching the cuff to the arm
Wrap the cuff around your upper arm, about 2-3 cm above the elbow. Place the cuff directly on your skin, as clothing can cause a weak pulse and result in incorrect measurements.
Constriction of the upper arm, caused by rolling up a shirt or t-shirt sleeve, can prevent accurate readings.
Secure the cuff with the Velcro strip so it's comfortable and not too tight. Rest your arm on the table (palm up) so that the cuff is at the same height as your heart. Make sure the tube is not kinked.
Blood pressure measurement
To measure your blood pressure, sit comfortably without crossing your legs, with your feet flat on the floor. Remain still and quiet during the measurement.
Press the ON/OFF button; all icons will appear on the display for two seconds, then switch to measurement and display "0" or the last measurement record. Start measurement; the cuff will inflate automatically. The heart symbol will flash on the LED. Once the measurement is complete, the results will appear on the display.
Measure your blood pressure at approximately the same time every day.
Don't measure immediately after exercise or bathing. Rest for twenty to thirty minutes before taking the measurement.
Cleaning and maintenance
Clean the monitor with a soft, dry cloth. Do not use any cleaning solutions.
Do not immerse the device or any component in water.
Clean the bracelet after each use. Wipe the inside (skin contact) of the bracelet thoroughly with a soft cloth lightly moistened with 75% ethyl alcohol three times. Replace the cloth after each use. Then air dry the bracelet.
Warnings
If you are taking any medications, consult your doctor to determine the best time to measure your blood pressure. Never change a prescribed medication without first consulting your doctor.
For people with irregular or unstable peripheral circulation problems due to diabetes, liver disease, hardening of the arteries, etc., there may be fluctuations in blood pressure values measured at the upper arm compared to the wrist.
Measurements may be affected if this device is used near televisions, microwave ovens, X-ray equipment, cell phones, or other devices with strong electrical fields. To avoid such interference, use the monitor at a sufficient distance from such devices or turn them off.
Wash hands before use.
Do not measure on the arm that has been using ME equipment monitoring at the same time, otherwise it may cause loss of function.
Batteries with liquid on their surface or that have been modified cannot be inserted into products.
Short circuiting of the battery must be avoided.
Battery life varies with ambient temperature and may be reduced at low temperatures.
Do not immerse the device or any of its components in water.
Do not expose the monitor to extremely hot or cold temperatures, humidity, or direct sunlight.
Do not subject the monitor to strong shocks.
Format
1 piece
Cod. MC1001
The monitor uses the oscillometric method to measure blood pressure.
The automatic electronic blood pressure monitor is intended for use by medical professionals or at home to monitor and display diastolic, systolic blood pressure and heart rate on adults.
Technical specifications
| Measurement method | Oscillometric measurement |
| Indication | Digital LED display |
| Measuring range | Pressure: 30-280 mmHg Heart rate: 40-199 beats/minute |
| Precision | Static pressure: ±3 mmHg Pulse: ±5% |
| Memory | 90 measurements |
| Diet | 4 x 1.5V batteries (LR03 or AAA) |
| Operating conditions | Temperature: 5°C to 40°C Relative humidity: 15-93% Atmospheric pressure: 70-106 kPa |
| Storage conditions | Temperature: -20°C to +55°C Relative humidity: 0-93% Atmospheric pressure: 50-106 kPa |
| Dimensions | approx. 93mm (W) x 161mm (H) x 47mm (D) |
| Classification | Type BF |
| Upper arm circumference | 22-32 cm |
| Operating mode | Continuous operation |
| AC adapter | Input: 100-240V, 50/60Hz, 0.2A Output: 6V 500mA |
How to use
Insert or replace batteries
Remove the battery cover. Insert new batteries into the battery compartment, making sure the polarity is correct. Close the battery cover. Use only LR03 or AAA batteries.
When the low battery indicator flashes on the display, replace the batteries.
Do not mix old and new batteries. This may shorten battery life or cause the device to malfunction.
Use only the specified batteries. The batteries supplied with the device are for testing the monitor's performance and may have a shorter lifespan.
Replace worn batteries with their polarities in the correct direction.
If you will not use the unit for a long period of time (about three months or more), remove the batteries.
Attaching the cuff to the arm
Wrap the cuff around your upper arm, about 2-3 cm above the elbow. Place the cuff directly on your skin, as clothing can cause a weak pulse and result in incorrect measurements.
Constriction of the upper arm, caused by rolling up a shirt or t-shirt sleeve, can prevent accurate readings.
Secure the cuff with the Velcro strip so it's comfortable and not too tight. Rest your arm on the table (palm up) so that the cuff is at the same height as your heart. Make sure the tube is not kinked.
Blood pressure measurement
To measure your blood pressure, sit comfortably without crossing your legs, with your feet flat on the floor. Remain still and quiet during the measurement.
Press the ON/OFF button; all icons will appear on the display for two seconds, then switch to measurement and display "0" or the last measurement record. Start measurement; the cuff will inflate automatically. The heart symbol will flash on the LED. Once the measurement is complete, the results will appear on the display.
Measure your blood pressure at approximately the same time every day.
Don't measure immediately after exercise or bathing. Rest for twenty to thirty minutes before taking the measurement.
Cleaning and maintenance
Clean the monitor with a soft, dry cloth. Do not use any cleaning solutions.
Do not immerse the device or any component in water.
Clean the bracelet after each use. Wipe the inside (skin contact) of the bracelet thoroughly with a soft cloth lightly moistened with 75% ethyl alcohol three times. Replace the cloth after each use. Then air dry the bracelet.
Warnings
If you are taking any medications, consult your doctor to determine the best time to measure your blood pressure. Never change a prescribed medication without first consulting your doctor.
For people with irregular or unstable peripheral circulation problems due to diabetes, liver disease, hardening of the arteries, etc., there may be fluctuations in blood pressure values measured at the upper arm compared to the wrist.
Measurements may be affected if this device is used near televisions, microwave ovens, X-ray equipment, cell phones, or other devices with strong electrical fields. To avoid such interference, use the monitor at a sufficient distance from such devices or turn them off.
Wash hands before use.
Do not measure on the arm that has been using ME equipment monitoring at the same time, otherwise it may cause loss of function.
Batteries with liquid on their surface or that have been modified cannot be inserted into products.
Short circuiting of the battery must be avoided.
Battery life varies with ambient temperature and may be reduced at low temperatures.
Do not immerse the device or any of its components in water.
Do not expose the monitor to extremely hot or cold temperatures, humidity, or direct sunlight.
Do not subject the monitor to strong shocks.
Format
1 piece
Cod. MC1001
| CREDIT CARD: | Pay securely with your credit card (including prepaid cards). | ||
| PAYPAL: | Pay for your order with your PayPal account, in one payment or by choosing to pay in installments (eligibility for Pay in 3 installments is subject to approval). Available for purchases between €30 and €2,000. |
||
| KLARNA: | Buy now, pay later with Klarna, pay in 3 interest-free installments. Split your payment into 3 installments to spread the cost of your purchase over time. The first payment will be made when your order is processed, while subsequent payments will be taken every 30 days from a debit or credit card of your choice. Minimum amount: €35 - Maximum amount: €1,500 |
||
| SHOP PAY: | Shop Pay is a payment service provider, owned by Shopify, that allows customers to save data such as their email address, credit card (or any card used), shipping address, and any billing information after completing a purchase. This tool is very useful because it allows customers to pay quickly and without having to re-enter all their data using an OTP code. How to pay in installments with Shop Pay? First, the customer must select the “Shop Pay installment” option, which gives the possibility of making the payment in 4 installments of the same amount. Once this is done, the customer must select the debit or credit card to pay the first installment and then the subsequent ones. |
||
| GPAY: | Google Pay (now part of Google Wallet) is a digital payment system that lets you make payments in physical stores, apps, and websites using your smartphone or smartwatch. To pay in-store, simply hold your device close to the contactless POS terminal and unlock it, without needing to open the app. For online payments, select Google Pay as your payment method and confirm your purchase. |
||
| WIRE TRANSFER: | You can pay for your order by bank transfer, entering the details received in the order confirmation email. Important - as the REASON FOR PAYMENT, please enter the "Order Reference" number. |
Bank details: BNL BNP PARIBAS BANK - Branch No. 3646 AVEZZANO IN THE NAME OF: STORNELLI FARMACY SNC OF DR. FRANCA STORNELLI & C REASON: ORDER NUMBER IBAN IT87D0100540440000000018373 |
|
| MARK: | Cash on delivery with a €5.00 supplement | ||
| SHIPPING COSTS: | For orders up to €39.90 shipping costs €4.90 | |
| For orders over €39.90 free shipping | ||
| Shipments via GLS/BRT express courier: | The order is usually prepared within the day following the order placement, with delivery expected within 48/72 hours after the order has been processed. Saturdays, Sundays and public holidays are excluded from these times. | |
| Further details: | For all information on shipping methods and international shipping costs, please visit the dedicated page. | |
NOTA BENE: le informazioni presenti nelle schede prodotto che potrete consultare in questo sito non devono essere interpretate come consulenza medica e non intendono, né possono sostituire le prescrizioni mediche. Le immagini, se presenti, sono fornite al solo scopo illustrativo e non costituiscono elemento identificativo.