{"product_id":"munus-medical-test-autodiagnostico-vitamina-d","title":"MUNUS MEDICAL SELF-DIAGNOSTIC TEST VITAMIN D","description":"\u003ch2\u003e ALLTEST\u003c\/h2\u003e\n\u003ch1\u003e VITAMIN D DEFICIENCY TEST\u003c\/h1\u003e\n\u003cdiv align=\"justify\"\u003e \u003cb\u003eDescription\u003c\/b\u003e\u003cbr\u003e Rapid immunochromatographic test for the semi-quantitative detection of 25-hydroxyvitamin D in human fingerstick blood.\u003cbr\u003e This test can provide a preliminary diagnostic result and can be used in screening for vitamin D deficiency. \u003cbr\u003eThis immunoassay is based on the principle of competitive binding. During the test, the mixture migrates upward on the membrane chromatographically by capillary action. The membrane is pre-coated with 25(OH)D antigens on the test line (T) region of the test strip. During the test, the 25(OH)D present in the sample will compete with the 25(OH)D present on the test line (T) due to the limited amount of anti-25OH vitamin D antibodies present in the conjugate. The higher the concentration of 25(OH)D in the sample, the fainter the T line will be.\u003cbr\u003e The result can be interpreted according to the color chart provided with this kit.\u003cbr\u003e With the procedural control function, a colored line will always appear in the control line area (C) to indicate that sufficient sample volume has been added and the membrane has been saturated.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eHow to use\u003c\/b\u003e\u003cbr\u003e Wash your hands with soap and rinse with clean warm water. \u003cbr\u003eAllow the package to reach room temperature before opening. Open the package, remove the test, and place it on a clean, flat surface. Perform the test within one hour of opening. Best results are obtained by performing the test immediately after opening the foil package.\u003cbr\u003e Remove the dropper, swab vial, sterile lancet, and alcohol wipe and place them near the test.\u003cbr\u003e Gently pull to remove the protective cap from the lancet. Use the alcohol wipe to clean the pad of your middle or ring finger where you will puncture your finger. Wait until the affected area is dry. Press the lancet on the side where the cap was removed; the tip automatically and safely retracts after use.\u003cbr\u003e Massage your hand towards the tip of the middle or ring finger that was pricked (without touching the puncture site) to obtain a drop of blood. \u003cbr\u003eTouch the capillary dropper to the blood, without squeezing the bulb. The blood will flow into the capillary dropper until it reaches the line indicated on the dropper. You can massage your finger again to obtain more blood if the fill line has not been reached. Try to avoid air bubbles as much as possible.\u003cbr\u003e Pour the collected blood into the sample well (S) on the device by pressing the dropper bulb.\u003cbr\u003e Wait until all the blood has flowed into the well. Unscrew the cap of the swab vial and add 2 drops of buffer to the swab well (B) on the device and start the timer.\u003cbr\u003e Wait for the colored line(s) to appear. Read the results after 10 minutes. Compare the intensity of the T-line with the \"Vitamin D Color Card\" provided in the kit to interpret the vitamin D level in your blood. Do not interpret the result after 20 minutes.\u003cbr\u003e\u003cbr\u003e \u003cu\u003eReading the results\u003c\/u\u003e\u003cbr\u003e\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"3\"\u003e\n\n\u003ctr align=\"center\"\u003e\n\n \u003ctd\u003e25-OH Vitamin D Level\u003c\/td\u003e\n\n\u003ctd\u003e Reference range (ng\/mL)\u003c\/td\u003e\n\n\u003ctd\u003e Reference range (nmol\/L)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Lacking\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 0-10\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 0-25\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Insufficient\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 10-30\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 25-75\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e Sufficient\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 30-100\u003c\/td\u003e\n\n\u003ctd align=\"center\"\u003e 75-250\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cbr\u003e - Deficient: Two distinct colored lines appear. One line is in the control region (C) and another line should appear in the test region (T). The line in the test region (T) is darker than or equal to the 10 ng\/mL line shown on the DEFICIENT color card provided in the kit.\u003cbr\u003e - Insufficient: Two colored lines appear. One line is in the control region (C) and another line should appear in the test region (T). The line in the test region (T) is darker than the 30 ng\/mL line and lighter than the 10 ng\/mL line, both of which are shown on the color card provided with the kit. \u003cbr\u003e- Sufficient: Two colored lines appear, one line should always appear in the control region (C) and another line should appear in the test region (T). The intensity of the line in the test region (T) is lighter than or equal to the 30 ng\/mL line shown on the color card.\u003cbr\u003e - Excessive: A colored line appears in the control region (C). No colored line appears in the test region (T). If the result is excessive vitamin D, it is recommended to consult your doctor.\u003cbr\u003e - Invalid: The control line does not appear. The most likely reasons for the control line not appearing are insufficient specimen volume or incorrect procedural techniques. Review the procedure and repeat the test with a new kit. If the problem persists, discontinue use of the kit immediately and contact your local distributor.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eWarnings\u003c\/b\u003e \u003cbr\u003ePlease read all the information in this leaflet before performing the test.\u003cbr\u003e For in vitro self-diagnostic use only.\u003cbr\u003e Do not eat, drink, or smoke in the specimen or kit handling area.\u003cbr\u003e Please do not use the test if the sealed package is damaged or opened.\u003cbr\u003e The kit is intended for use as a preliminary test and repeated abnormal results should be discussed with a doctor or specialist.\u003cbr\u003e Strictly follow the indicated timeframes.\u003cbr\u003e Use the test only once. Do not disassemble or touch the test window on the holder.\u003cbr\u003e The kit must not be frozen or used beyond the expiration date printed on the package.\u003cbr\u003e Keep out of reach of children.\u003cbr\u003e Once used, the test must be disposed of according to local regulations.\u003cbr\u003e The Vitamin D Deficiency Test provides only a semiquantitative analytical result. A secondary analytical method must be used to confirm the result. \u003cbr\u003eTechnical or procedural errors, as well as interfering substances in the blood sample, may cause erroneous results. As with all diagnostic tests, all results must be evaluated in conjunction with other clinical data available to your doctor. In the event of a questionable result, clinical testing using additional analytical methods is necessary.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eConservation\u003c\/b\u003e\u003cbr\u003e Store packaged at room temperature or refrigerated (2-30°C).\u003cbr\u003e Do not freeze.\u003cbr\u003e The test is stable until the expiration date printed on the sealed pouch or unopened box. The test must remain in the sealed pouch until use. Do not use beyond the expiration date.\u003cbr\u003e Shelf life in intact packaging: 24 months.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eFormat\u003c\/b\u003e\u003cbr\u003e The package contains:\u003cbr\u003e - test;\u003cbr\u003e - dropper;\u003cbr\u003e - swab;\u003cbr\u003e - alcohol wipe;\u003cbr\u003e - hands;\u003cbr\u003e - package leaflet;\u003cbr\u003e - color card.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eBibliography\u003c\/b\u003e \u003cbr\u003e1. Holick MF (March 2006). High prevalence of vitamin D inadequacy and implications for health. Mayo Clinic Proceedings. 81(3):353–73.\u003cbr\u003e 2. Eriksen EF, Glerup H (2002). Vitamin D deficiency and aging: implications for general health and osteoporosis. Biogerontology. 3 (1-2): 73–7.\u003cbr\u003e 3. Grant WB, Holick MF (June 2005). Benefits and requirements of vitamin D for optimal health: a review. Alternative Medicine Review.10(2):94–111.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eCod.\u003c\/b\u003e MM-OVD-402H\u003c\/div\u003e","brand":"MUNUS INTERNATIONAL SRL","offers":[{"title":"Default Title","offer_id":50734709440846,"sku":"986885186","price":9.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0845\/6214\/9710\/files\/TE009-291438.jpg?v=1768763868","url":"https:\/\/farmaspeed.it\/en\/products\/munus-medical-test-autodiagnostico-vitamina-d","provider":"Farmaspeed","version":"1.0","type":"link"}