FISIOCHAMBER VISION PLUS
INFANT 0-3 years
Description
Antistatic Chamber for use with MDI pressurized metered dose inhalers.
How to use
Before use, carefully inspect all parts, valves, and vents. Replace if defective.
Remove the cap from the metered dose aerosol inhaler (MDI). Shake the MDI.
Insert MDI into the “Proper Fit” universal adapter and make sure it fits tightly.
Remove the inhalation chamber cover.
Insert the mask into the mouthpiece of the inhalation chamber.
Check that the safety exhalation valve opens (otherwise replace the mask).
Apply the mask to your face and make sure it fits tightly.
If the patient can cooperate, place the mouthpiece only in the mouth and make sure it is sealed properly.
Inhale and exhale normally.
Then press the inhaler once and begin to inhale slowly.
Observe the VISION VALVE carefully: its movement indicates the act of inhalation.
After pressing the inhaler, keep the mask tightly closed to your face for at least 5 breaths.
Before pressing the inhaler again, wait and repeat this step following the inhaler's or doctor's instructions. Always follow the dosage prescribed by your doctor.
Cleaning, disinfection and sterilization
Wash before first use and at least once a week following the instructions.
Remove all parts as shown and open the chamber.
Soak the parts for 15 minutes in clean warm water and mild detergent.
Shake gently.
Rinse all parts with clean water. Shake off excess water and let air dry.
Do not use drying cloths.
Before reassembling, make sure the parts are thoroughly dry.
Reassemble the parts as shown.
Disinfection: by immersion in 3% hydrogen peroxide for 30 minutes.
Sterilization: sterilizable with a steam cycle at 121°C or with ETO gas or with a plasma system.
Warnings
- Always follow the instructions before each use.
- Do not leave Fisio Chamber Vision or any part of it within the reach of children: some parts are quite small and could be swallowed.
- The product must be replaced after 2 years of continuous use at the latest.
- Replace the product when it is not in its original condition, due to any damage, valve tightness, environmental and storage conditions and frequency of use.
- The use and sale of Fisio Chamber Vision are permitted under the strict supervision of personnel trained in its use.
- Monitor the patient during use.
- To maintain maximum efficiency of the device, we recommend replacing the valve block every 12 months.
Conservation
Store the product in a dry and clean place.
Relative humidity 30% - 80%.
Storage temperature 0°C-40°C.
Avoid prolonged exposure to high temperatures.
Do not expose to: organic solvents, ionizing radiation, ultraviolet light, direct light and sunlight.
Shelf life of intact packaging: 60 months.
Shelf life after opening: 24 months.
Cod. KM 1322B
Antistatic Chamber for use with MDI pressurized metered dose inhalers.
How to use
Before use, carefully inspect all parts, valves, and vents. Replace if defective.
Remove the cap from the metered dose aerosol inhaler (MDI). Shake the MDI.
Insert MDI into the “Proper Fit” universal adapter and make sure it fits tightly.
Remove the inhalation chamber cover.
Insert the mask into the mouthpiece of the inhalation chamber.
Check that the safety exhalation valve opens (otherwise replace the mask).
Apply the mask to your face and make sure it fits tightly.
If the patient can cooperate, place the mouthpiece only in the mouth and make sure it is sealed properly.
Inhale and exhale normally.
Then press the inhaler once and begin to inhale slowly.
Observe the VISION VALVE carefully: its movement indicates the act of inhalation.
After pressing the inhaler, keep the mask tightly closed to your face for at least 5 breaths.
Before pressing the inhaler again, wait and repeat this step following the inhaler's or doctor's instructions. Always follow the dosage prescribed by your doctor.
Cleaning, disinfection and sterilization
Wash before first use and at least once a week following the instructions.
Remove all parts as shown and open the chamber.
Soak the parts for 15 minutes in clean warm water and mild detergent.
Shake gently.
Rinse all parts with clean water. Shake off excess water and let air dry.
Do not use drying cloths.
Before reassembling, make sure the parts are thoroughly dry.
Reassemble the parts as shown.
Disinfection: by immersion in 3% hydrogen peroxide for 30 minutes.
Sterilization: sterilizable with a steam cycle at 121°C or with ETO gas or with a plasma system.
Warnings
- Always follow the instructions before each use.
- Do not leave Fisio Chamber Vision or any part of it within the reach of children: some parts are quite small and could be swallowed.
- The product must be replaced after 2 years of continuous use at the latest.
- Replace the product when it is not in its original condition, due to any damage, valve tightness, environmental and storage conditions and frequency of use.
- The use and sale of Fisio Chamber Vision are permitted under the strict supervision of personnel trained in its use.
- Monitor the patient during use.
- To maintain maximum efficiency of the device, we recommend replacing the valve block every 12 months.
Conservation
Store the product in a dry and clean place.
Relative humidity 30% - 80%.
Storage temperature 0°C-40°C.
Avoid prolonged exposure to high temperatures.
Do not expose to: organic solvents, ionizing radiation, ultraviolet light, direct light and sunlight.
Shelf life of intact packaging: 60 months.
Shelf life after opening: 24 months.
Cod. KM 1322B
| CREDIT CARD: | Pay securely with your credit card (including prepaid cards). | ||
| PAYPAL: | Pay for your order with your PayPal account, in one payment or by choosing to pay in installments (eligibility for Pay in 3 installments is subject to approval). Available for purchases between €30 and €2,000. |
||
| KLARNA: | Buy now, pay later with Klarna, pay in 3 interest-free installments. Split your payment into 3 installments to spread the cost of your purchase over time. The first payment will be made when your order is processed, while subsequent payments will be taken every 30 days from a debit or credit card of your choice. Minimum amount: €35 - Maximum amount: €1,500 |
||
| SHOP PAY: | Shop Pay is a payment service provider, owned by Shopify, that allows customers to save data such as their email address, credit card (or any card used), shipping address, and any billing information after completing a purchase. This tool is very useful because it allows customers to pay quickly and without having to re-enter all their data using an OTP code. How to pay in installments with Shop Pay? First, the customer must select the “Shop Pay installment” option, which gives the possibility of making the payment in 4 installments of the same amount. Once this is done, the customer must select the debit or credit card to pay the first installment and then the subsequent ones. |
||
| GPAY: | Google Pay (now part of Google Wallet) is a digital payment system that lets you make payments in physical stores, apps, and websites using your smartphone or smartwatch. To pay in-store, simply hold your device close to the contactless POS terminal and unlock it, without needing to open the app. For online payments, select Google Pay as your payment method and confirm your purchase. |
||
| WIRE TRANSFER: | You can pay for your order by bank transfer, entering the details received in the order confirmation email. Important - as the REASON FOR PAYMENT, please enter the "Order Reference" number. |
Bank details: BNL BNP PARIBAS BANK - Branch No. 3646 AVEZZANO IN THE NAME OF: STORNELLI FARMACY SNC OF DR. FRANCA STORNELLI & C REASON: ORDER NUMBER IBAN IT87D0100540440000000018373 |
|
| MARK: | Cash on delivery with a €5.00 supplement | ||
| SHIPPING COSTS: | For orders up to €39.90 shipping costs €4.90 | |
| For orders over €39.90 free shipping | ||
| Shipments via GLS/BRT express courier: | The order is usually prepared within the day following the order placement, with delivery expected within 48/72 hours after the order has been processed. Saturdays, Sundays and public holidays are excluded from these times. | |
| Further details: | For all information on shipping methods and international shipping costs, please visit the dedicated page. | |
NOTA BENE: le informazioni presenti nelle schede prodotto che potrete consultare in questo sito non devono essere interpretate come consulenza medica e non intendono, né possono sostituire le prescrizioni mediche. Le immagini, se presenti, sono fornite al solo scopo illustrativo e non costituiscono elemento identificativo.